Performance Objective
| 
			 Data Requirements  | 
			
			 Success Criteria  | 
			
			 Results  | 
		|
|---|---|---|---|
| 
			 Qualitative Performance Objectives  | 
		|||
| 
			 Determine if RCDM samplers recover same chemical parameters as PDB samplers and LF.  | 
			
			 Identify chemical parameters recovered by RCDM samplers, PDB samplers, and LF.  | 
			
			 Chemical parameters detected in PDB and LF are the same detected by RCDM samplers.  | 
			
			 Criteria met  | 
		
| 
			 Determine if RCDM membrane integrity is maintained over the course of equilibration.  | 
			
			 Observe sampler membranes for perforations.  | 
			
			 No perforations noted during the course of the test.  | 
			
			 Criteria met  | 
		
| 
			 Quantitative Performance Objectives  | 
		|||
| 
			 Determine if RCDM samplers recover the same  concentrations as LF.  | 
			
			 Measure inorganic and organic compound concentrations recovered by RCDM samplers and LF.  | 
			
			 NSD at p<0.05 between chemical concentrations recovered by the RCDM samplers and LF.  | 
			
			 Criteria met for 96% of all chemicals tested  | 
		
| 
			 Determine if RCDM samplers recover the same  concentrations as PDB samplers.  | 
			
			 Measure VOC concentrations recovered by RCDM samplers and PDB samplers.  | 
			
			 NSD at p<0.05 between VOC concentrations recovered by the RCDM sampler and the PDB sampler.  | 
			
			 Criteria met for 100% of all chemicals tested  | 
		
| 
			 Determine if RCDM samplers can sample low concentrations.  | 
			
			 Measure concentrations of chemicals near detection limits.  | 
			
			 Concentrations within 2-5 times the detection limit can be  detected.  | 
			
			 Criteria met  | 
		
| 
			 Determine if RCDM samplers take significantly less field time to collect samples than LF.  | 
			
			 Measure time needed to collect samples using RCDM samplers and LF.  | 
			
			 Comparison of field time required to sample RCDM samplers versus LF should be 5 times shorter.  | 
			
			 Criteria met  |