Objective
The objective of this project is to test and demonstrate the performance of the Evaporative Cooling Infrastructure (ECI), a technology that has been developed to abate the urban heat island effect on Department of War facilities via passive cooling. Extreme heat conditions significantly degrade warfighter mission readiness by reducing soldier training days with undue stress on capabilities. Employing cost-effective cooling strategies using technology and updated building codes would ideally reduce installation energy costs, improve life cycle effectiveness of buildings and systems, and improve quality of life for military personnel.
Technology Description
First, this project will conduct a preliminary analysis of the ECI cooling potential through a modeling approach. Secondly, the system’s wicking material will be optimized to ensure optimum performance as an integral part of the ECI. The ECI combines two established technologies, a novel water wicking material and permeable pavement, to facilitate passive cooling using stormwater (typically an unused water source). Stormwater enters the system through voids in the permeable pavement surface and is stored within the gravel layers below. Captured stormwater is transferred to the surface via the strong capillary action provided by the wicking material, where it can be transferred to the surrounding atmosphere via evaporation (providing a cooling effect). This process is controllable by using a valve to manage water access to the wicking material as desired. In locations with less consistent rainfall, in particular during the heat of the summer, a water harvesting system can be used to provide additional storage of stormwater for use in the ECI.
Benefits
The urban heat island and extreme heat events across the world have the potential for substantially disrupting military operations. Innovative technologies such as the ECI have the potential to mitigate these effects by cooling ambient temperatures and thus reducing heat stress on military personnel. The ECI has strong promise for achieving such impacts, with its core wicking material producing evaporation rates similar to open water, essentially the upper threshold possible for evaporative cooling techniques. The ability of the ECI to be “turned on” during times of greatest need is a significant advantage of this technology, allowing more targeted interventions for extreme heat. Finally, the ECI can be implemented in locations where other approaches (such as tree planting) may not be viable, e.g., the edges of airport runways, outdoor installation points of entry, in dense areas where space is limited, and where there is a need for robust surfaces capable of use for activities such as parking. (Anticipated Project Completion - 2028)